Hirschmann M-SFP-LH / LC-EEC SFP
Mahsulot tavsifi
Ta'rif: | Sfp tolaoptic gigapit Ethernet transferivi LH, kengaytirilgan haroratning kengayishi |
Port turi va soni: | LC Ulagich bilan 1 x 1000 Mbit / s |
Tarmoq hajmi - kabel uzunligi
Bitta rejim tolasi (lh) 9/125 mkm (uzoq piralik transpeel): | 23 - 80 km (havolani 1550 nm = 5 - 22 db; a = 0,25 db / km / 19 PS / (nm * km)) |
Quvvat talablari
Ishli ishlaydigan kuchlanish: | Murvat orqali elektr ta'minoti |
Atrof-muhit sharoitlari
MTBF (Sr-332 chiqarish 3) @ 25 ° C: | 482 yil |
Harorat harorati: | -40- + 85 ° C |
Saqlash / transport harorati: | -40- + 85 ° C |
Nisbiy namlik (kondensatsiya qilinmaydigan): | 5-95% |
Mexanik qurilish
O'lchamlar (WXHXD): | 13.4 mm x 8.5 mm x 56.5 mm |
Mexanik barqarorlik
IEC 60068-2-6 tebranishi: | 1 mm, 2 Hz-13.Z, 90 minut; 0,7 g, 13.2 Hz-100 Hz, 90 minut; 3,5 mm, 3 hz-9 hz, 10 tsikl, 1 oktava / min .; 1 g, 9 Hz-150 Hz, 10 tsikl, 1 oktava / min |
IEC 60068-2-27 zarba: | 15 g, 11 ms davomiyligi, 18 ta zarba |
EMC aralashmasi immuniteti
En 61000-4-2 elektrostatik oqindi (ESD): | 6 kV bilan bog'lanishni tugatish, 8 kV havo zaryasi |
En 61000-4-3 Elektromagnit maydon: | 10 V / m (80-1000 MGts) |
En 61000-4-4 Tez ko'chib o'tish (portlash): | 2 kV elektr uzatish liniyasi, 1 kV ma'lumotlar liniyasi |
En 61000-4-5 Qishloq kuchlanish: | Quvvat liniyasi: 2 kV (satr), 1 kV (satr (satr), 1 kV ma'lumotlar liniyasi |
En 61000-4-6 Immunitet: | 3 V (10 kHz-150 khz), 10 Vz (150 khz-80 mhz) |
Tasdiqlash
Axborot texnologiyalari uskunasining xavfsizligi: | En60950 |
Xavfli joylar: | Jamg'armaga qarab |
Kemaverding: | Jamg'armaga qarab |
Etkazib berish va aksessuarlarning ko'lami
Yetkazib berish doirasi: | SFP moduli |
Variantlar
Element # | Tur |
943898001 | M-SFP-LH / LC-EEC |